Profibus DP Drive E1130-DP-HC Linmot Việt Nam

E1130-DP-HC

Profibus DP Drive (72V/15A)

Article no.: 0150-1668   

 

Compact drive for an ideal use in point-to-point applications.
Technical data
Interface Profibus DP
Motor Supply 24...72 VDC
Motor Current 15 A
Analog Inputs 0..10V 2
Analog Inputs +-10V 0
Digital In and Outputs 8 / 8
External Encoders A/B/Z (RS422)
SinCos
Mechanical data
Height 40 mm (1.57 in)
Length 255 mm (10.04 in)
Width 180 mm (7.09 in)
Weight 1418 g (3.13 lb)
Certificates CE
UKCA

LIST CODE

100% China
Origin
DYH/ DIYIHU
Vietnam
Model : LXZ2-Φ 180
Current Transformer
Note : báo giá theo nameplate
100% Finland Origin Vaisala Vietnam DPT146 A1DCX110A0A
Dewpoint and Pressure Transmitter, 1...12 bar, Td -70...30 °C
Mechanical Connection: ISO G1/2" Process Connection Thread
Measurement Parameters: Dewpoint, Pressure, ppm, Dewpoint at atm
Analog Output Ch1 & Ch2 + RS-485 as Standard: 4...20 mA
Analog Output Parameter or Function for Ch1: Dew Point -60...+40 °C (-76 ...+104 °F) Td/f
Analog Output Parameter or Function for Ch2: Absolute Pressure, free scale (confirm when order)
Metric Units
Cable for Analog Outputs and Power Supply (Port I): 0.3 m (1.0 ft) M8 Shielded Cable with Open Wires
No Cable for RS485 Line and Power Supply (Port II)
No Installation Accessories ONLY for ISO1/2" ThreadNo Special Features
No User's Guide
100% EU/ USA Origin Interfaceforce Vietnam Model: 1010ACK-12,5KN
Load cell
100% EU/ USA Origin Interfaceforce Vietnam Model: IFFTS20-100NM Torque Measurement System
Reaction torque measuring flange
Note: Please check your type before ordering
100% Finland Origin Vaisala Vietnam DMT152 B1DEE1XA100A1X
DMT152 Transmitter for Low Dewpoint with a measurement range of -80 to -20°C
Mechanical Connection: NPT 1/2" Thread
Measurement Parameters: Td/f, ppm
Analog Output Ch1 & Ch2 + RS-485 as Standard: 4...20 mA
Analog Output Parameter or Function for Ch1: 0...500 ppm
Analog Output Parameter or Function for Ch2: 0...500 ppm
Metric Units
Pressure Setting for ppm Calculation: Special Pressure Max 50 bar(a), please define:
Cable for Analog Outputs and Power Supply (Port I): Shielded Cable, 2m, snap in connector
No Cable for RS485 Line and Power Supply (Port II): No Service Cable
No Installation Accessories ONLY for ISO1/2" Thread
No No Special Labels
Cardboard Box
Quick Reference Guide DMT152
100% USA Origin Temposonics/MTS Vietnam Code: RH5MA0800M01D601A100
Temposonics® R-Series V Rod
RHM0800MD601A01 is no longer
Note: Recheck delivery time before order